Experts estimate that in a plant with no active steam trap testing and repair program, 50% of the traps are blowing steam. With monthly inspection and prompt repair, this figure can be reduced to under 3%. Example: One trap with a 3/32" orifice operating at 100 psi can lost almost 30 lbs. of steam per hour. At $8/1,000 lbs. of steam, that can result in a loss of over $2,000 a year from each faulty trap of that type.
Is your company willing to accept unnecessary steam
losses indefinitely?
You can regain an energy edge with steam traps engineered and developed for maximum efficiency and durability.
Statistics compiled from many long-term field tests of Gestra traps verify the achievement of these goals! Millions installed worldwide.
Upgrading the quality of steam traps is an essential contribution to improved plant efficiency (energy conservation + proper system function).
Choosing the incorrect trap will cost conservatively 2 – 4 lbs/hour of live steam loss at each location in the plant (17,520 – 35,040 lbs/year). This is the minimum amount of operating steam loss inherent in the design of inverted bucket and thermodynamic disc traps in low load applications. Some steam traps are designed to continuously lose steam every hour they operate, while others are designed for zero steam loss.
Types of steam trap designs
- Thermostatic (bimetallic)
- Thermostatic (membrane)
- Ball float and thermostatic
- Inverted bucket (live steam loss $ $ $)
- Thermodynamic disc (live steam loss $ $ $)
The Gestra thermostatic steam trap Solution
MK Series - Ultimate versatility and performance
# of capsules |
HOT condensate load * |
COLD start up load * |
Model |
1 |
1,000 lbs /hour |
2,400 lbs/hour |
MK45-2 |
2 |
1,760 lbs/hour |
4,000 lbs/hour |
MK35/2S or MK25/2S |
3 |
2,550 lbs/hour |
6,000 lbs/hour |
MK35/S23 or MK25/2S3 |
4 |
5,200 lbs/hour |
10,500 lbs/hour |
MK25/2 |
9 |
9,000 lbs/hour |
17,500 lbs/hour |
MK25/2S |
4 as pilots |
180,000 lbs/hour |
330,000 lbs/hour |
TK24 |
*at 40 psi different pressure
BK Series - Ultimate performance
|
MK Series |
BK Series |
Zero live steam loss |
Yes |
Yes |
Reliable proven performance |
Millions installed worldwide |
|
Mount in any position |
Yes |
Yes |
Full pressure range handled |
Yes |
Yes |
Maximum parts interchangeability between models |
Minimal inventory requirements |
|
Resistant to damage from |
Yes |
Yes |
Fast start up and fast |
Yes |
Yes |
Built in strainer |
Yes |
Yes |
Built in check valve |
Yes - MK45 |
Yes |
Universal connectors available |
Yes |
Yes |
Saturated steam |
Yes - up to 465 psig |
Yes – up to 4350 psig |
Superheated steam |
No |
Yes – up to 4350 psig |
Pressure differential allowable |
2 - 320 psig |
2 – 3625 psig |
Maximum allowable back pressure |
Up to 99% |
Up to 30% |
Applications: steam drip lines / heat exchangers / heat tracers / air vents / special